Isolation Materials

E-A-R's ISODAMP and ISOLOSS materials are formulated to reduce vibrations and dissipate shock energy at a very rapid rate. They are available in many forms—sheets, rolls, die-cut and custom-molded parts. Applications range from noise control in demanding vehicle environments to eliminating unwanted energy from miniaturized precision equipment.

ENLARGE IMAGE

Description:
ISODAMP C-1002 - Vinyl Solid ISOLOSS HD - Thermoset
ISODAMP C-1105 - Vinyl Solid ISOLOSS SL - Thermoset
ISODAMP C-1100 - Vinyl Solid  

Typical Properties (English Table)
* click the links below to see catalog pages for the products *
Product
(Complete Product Catalog)
ISODAMP
C-1002
ISODAMP
C-1105
ISODAMP
C-1100
ISOLOSS
HD
ISOLOSS
SL-20100
-----
-----
Hardness Nominal
ASTM D2240
15 sec post impact at 73F

Shore A Durometer

56 63 70 58 — —
Shore OO — — — — — —
Flammability
UL 94 0.06 in thick
Listed
V-0
Listed
V-0
Listed
V-0
Listed
HB
Not
Rated
-----
-----
FAR 25.853 (a) Appendix F
Part I (a) (1) (12 sec) Meets at Thickness
0.030 in — — — — —
FAR 25.853 (b-3) Meets at Thickness 0.015 in — — — — —
FMVSS-302 Meets at Thickness 0.015 in 0.060 in 0.060 in 0.125 in — —
Dynamic Properties
ASTM D5279
at 10 Hz, 0.3% Amplitude
Glass Transition Temperature (F)
1 9 36 18 — —
Max Loss Factor at 10 Hz .93 at 46F .93 at 63F .79 at 77F .94 at 54F — —
Compression Set (%)
ASTM D395 Method B

22 hr at 72F

14 23 24 4.5 3 -----
22 hr at 158F, (*50C) 62 51 55 6.1 8 -----
Compression Load
Deflection (psi)
ASTM D575 at 0.2 in/min

10%

71 92 155 82 18 ---
20% 244 320 495 180 35 ---
30% 534 694 1033 305 57 ---
Compression Modulus 842 1090 1838 845 — —
Tensile Strength (psi)
ASTM D638

20 in/min at 72F

1574 1807 2058 1300 — —
Tear Strength (lbf/in)
ASTM D1004
202 241 305 218 — —
Temperature Range (F)
Peak Performance
55 to 105 80 to 130 95 to 145 55 to 105 — —
Recommended Max. Intermittent 180 180 180 225 — —
RoHS Compliant Yes Yes Yes Yes — —

The data listed in this materials summary are typical or average values based on tests conducted by independent laboratories or by the manufacturer. They are indicative only of the results obtained in such tests and should not be considered as guaranteed maximums or minimums. Materials must be tested under actual service to determine their suitability for a particular purpose.

ISODAMP and ISOLOSS are trademarks licensed to Aearo Company